TLTDE-lighttech

About Us

To build LED products whose light output and color hold their specification over service life, by treating thermal design and component derating as the core of the engineering.

Who We Are

About Our Company

TDE-lighttech manufactures LED display systems and lighting products: fine pitch indoor video wall modules and cabinets, outdoor display and billboard systems, transit and wayfinding signage, and industrial and commercial luminaires including high bay, area, flood and linear fixtures. Production covers surface mount assembly of LED modules, driver and power supply integration, enclosure fabrication and sealing, optical and thermal assembly, module calibration and burn-in testing. We bin diodes for brightness and color consistency, calibrate modules so a wall reads as one surface, and document thermal performance because junction temperature governs how long the product keeps its output.

Integrators and facility owners around work with TDE-lighttech because LED products are usually judged years after purchase. A display that was uniform at commissioning and patchy after two summers had a thermal or binning problem from the start. A high bay fixture whose output faded early was run with its driver too hot. We design the heat path deliberately, derate drivers for the ambient conditions the product will actually see, seal outdoor enclosures to tested ratings with serviceable access, and burn in product before shipment so early failures happen in our plant rather than on a roof.

LED Display & Lighting - Service

Core Capabilities

  • Control and processing firmware versions are recorded against each order.
  • Ingress protection is verified by test on the production enclosure.
  • LED diodes are binned for brightness and wavelength before assembly.
  • Junction and case temperatures are measured on the built assembly.
  • Spare parts and module revisions are tracked for serviceability later.
  • Failures during burn-in are root caused before the batch is released.

Compliance

Standards & Credentials

  • ISO 9001 Quality Management
  • IES LM-80 LED Lumen Maintenance Testing
  • IES TM-21 Lifetime Projection Methods
  • UL 8750 LED Equipment Safety
  • IEC 60529 Ingress Protection Ratings
  • RoHS & REACH Material Compliance

We tell you when a lower pitch is a waste of money.

Every panel burned in before it leaves the factory

  • ISO 9001 Quality Management
  • IES LM-80 LED Lumen Maintenance Testing
  • IES TM-21 Lifetime Projection Methods
  • UL 8750 LED Equipment Safety
  • IEC 60529 Ingress Protection Ratings

Track Record

By The Numbers

50,000 m2Display Area Produced
72 hrStandard Burn-In Duration
IP65Outdoor Cabinet Rating
15 yrsLED Product Engineering Experience

Our Mission

To build LED products whose light output and color hold their specification over service life, by treating thermal design and component derating as the core of the engineering.

Sectors

Who We Serve

Indoor fine pitch and outdoor billboard products share the same test discipline.

  • Sign & Display Integrators
  • Stadium & Venue Operators
  • Retail Chain Developers
  • Transit & Transportation Authorities
  • Industrial Facility Owners
  • Broadcast & Studio Builders
  • Architectural Lighting Designers
  • Commercial Electrical Contractors

Client Feedback

What Clients Say

Replacement panels blend into the wall without recalibration, two years after installation. That is the detail that separates a real manufacturer from an assembler.
A
A. PetrosyanTechnical Director, Display Integrator
They derated the drivers for the actual temperature at our roof level, which nobody else asked about. Three years in, we have not replaced one.
J
J. ThibodeauxFacilities Manager, Distribution Client
Our curved lobby element had thermal and access problems that they flagged during design. Solving them on paper saved a very awkward site discovery.
M
M. HaugenPrincipal, Lighting Design Practice

Specifying A Display Or Lighting Package?

Send the application details to TDE-lighttech and we will return a design with measured thermal data and photometric information.

Services

An LED product fails at its driver, its solder joints or its junction temperature, almost never at the diode itself. Our designs address heat path, driver derating and conformal protection from the first thermal model.

Our Advantages

Why Clients Choose Us

Burn-In Before Shipment

Extended run-in catches infant mortality in our plant, which is the difference between a warranty statistic and a roof access call.

Outdoor Ratings Actually Tested

Ingress protection is validated rather than assumed from a gasket specification, and surge protection is sized for genuine installation exposure.

Thermal Design Verified By Measurement

Junction and case temperatures are measured rather than estimated, because junction temperature is what actually governs lumen maintenance.

Serviceable, Not Disposable

Products are built so a driver or module can be replaced in the field, instead of requiring the whole fixture or cabinet to be discarded.

Drivers Derated Properly

Drivers are selected with margin for the installed ambient, addressing the single most common cause of premature LED product failure.

Diodes Binned, Modules Calibrated

Brightness and color binning plus module-level calibration keep a wall reading as a single surface, including after a panel is replaced years later.

Drivers Derated Properly

Power supplies run with real margin against their rating, since the driver, not the diode, is what usually fails first in a display or luminaire.

Outdoor Ratings Actually Tested

Enclosures are tested for ingress and thermal cycling as built, not credited with the rating of an individual component inside them.

Diodes Binned, Modules Calibrated

Brightness and wavelength binning plus per-module calibration is what stops a large wall looking like a patchwork two years into its life.

Our Services

What We Do

Outdoor Display & Billboard Systems
Step 01

Outdoor Display & Billboard Systems

Weather-rated display cabinets with tested ingress protection, ultraviolet stable masking and louvers, surge protection, thermal management for solar gain and serviceable module access. Outdoor failures cluster around water ingress and heat, so sealing design and internal airflow receive as much attention as the optics.

Request a Quote
Burn-In, Testing & Quality Documentation
Step 02

Burn-In, Testing & Quality Documentation

Extended burn-in of finished product, electrical safety and photometric verification, ingress protection validation, color uniformity measurement and documented quality records. Early-life failures are found in our plant rather than on a customer roof, which is far cheaper for everyone involved.

Request a Quote
LED Driver & Power Supply Integration
Step 03

LED Driver & Power Supply Integration

Selection and integration of drivers and power supplies with attention to derating, ripple, dimming protocol compatibility, inrush, surge immunity and operating temperature. Drivers are the most common failure point in LED products, and running them near their thermal limit is how a ten-year product becomes a three-year one.

Request a Quote
Industrial & Commercial Luminaires
Step 04

Industrial & Commercial Luminaires

Manufacture of high bay, low bay, area, flood, linear and task luminaires with documented photometric performance, driver derating for the installed ambient temperature and heat sink design verified by thermal testing. Fixtures are built for driver replacement rather than as disposable sealed assemblies.

Request a Quote
Fine Pitch Indoor Display Manufacturing
Step 05

Fine Pitch Indoor Display Manufacturing

Production of indoor video wall modules and cabinets in close pixel pitches with binned diodes, module-level calibration for brightness and color uniformity, and cabinet construction designed for front or rear service access. Calibration data is stored with the module, so a replacement panel blends with the wall instead of standing out.

Request a Quote
Custom Signage & Architectural Fabrication
Step 06

Custom Signage & Architectural Fabrication

Bespoke LED signage, channel lettering, curved and irregular display surfaces, and architectural lighting elements fabricated to designer intent with structural and electrical engineering support. Custom geometry introduces thermal and serviceability problems that have to be solved during design rather than discovered at installation.

Request a Quote
Control, Processing & Integration
Step 07

Control, Processing & Integration

Video processing, receiving card configuration, brightness and color management, lighting control protocol integration, scheduling and network monitoring, with commissioning support for integrators. Content and control configuration are documented, because a display handed over without its configuration becomes unmaintainable.

Request a Quote
Thermal Design & Lifetime Testing
Step 08

Thermal Design & Lifetime Testing

Thermal modeling and measurement of junction and case temperatures, heat sink and enclosure design, and lifetime projection using recognized LED lumen maintenance test and extrapolation methods. Projected life figures are only meaningful alongside the drive current and temperature they were derived at, so we state both.

Request a Quote

Compliance

Standards & Credentials

  • ISO 9001 Quality Management
  • IES LM-80 LED Lumen Maintenance Testing
  • IES TM-21 Lifetime Projection Methods
  • UL 8750 LED Equipment Safety
  • IEC 60529 Ingress Protection Ratings
  • RoHS & REACH Material Compliance

We tell you when a lower pitch is a waste of money.

Our Process

How We Work

  1. 1

    Define The Application

    We establish viewing distance and pitch, brightness requirement, ambient light, mounting and service access, environment, control system and any photometric or code requirement that applies.

  2. 2

    Design & Prototype

    Optical, thermal, electrical and mechanical design is developed with thermal modeling and a prototype or sample module for approval, including measured temperatures and photometric data.

  3. 3

    Manufacture & Calibrate

    Modules are assembled, drivers integrated, enclosures fabricated and sealed, and modules calibrated for brightness and color with calibration data retained against each unit.

  4. 4

    Burn In, Test & Support

    Product is burned in and tested electrically, photometrically and for ingress protection, then shipped with documentation and commissioning support for installation and control configuration.

Specifying A Display Or Lighting Package?

Send the application details to TDE-lighttech and we will return a design with measured thermal data and photometric information.

Projects

Outdoor displays face water ingress, ultraviolet degradation, thermal cycling and wind loading. We build and test for those conditions, with sealed cabinets, service access and surge protection sized for real installations.

Projects & Case Studies

Selected Work

High Bay Luminaires For Distribution Center
Industrial Lighting

High Bay Luminaires For Distribution Center

Fixtures were produced with drivers derated for the measured ambient at roof level, heat sinks verified by thermal testing, and field-replaceable drivers. Photometric data supported the lighting design calculation submitted for approval.

Scope of Work
LED Display & Lighting
Category
Industrial Lighting
Fine Pitch Wall For Broadcast Studio
Broadcast

Fine Pitch Wall For Broadcast Studio

A close pitch video wall was produced with tightly binned diodes and module calibration data stored per panel, plus front service access for a studio with no rear clearance. Replacement panels installed since have blended without recalibrating the wall.

Scope of Work
LED Display & Lighting
Category
Broadcast
Curved Architectural Display Element
Architectural

Curved Architectural Display Element

A curved display surface for a building lobby required custom module geometry. Thermal and service access problems were resolved during design, and structural and electrical engineering support was provided to the installing contractor.

Scope of Work
LED Display & Lighting
Category
Architectural
Outdoor Billboard System For Transit Hub
Out-Of-Home Media

Outdoor Billboard System For Transit Hub

A weather-rated display was built with validated ingress protection, surge protection sized for the exposed location, internal airflow managed for solar gain and serviceable modules accessible from a single side given the structural constraints.

Scope of Work
LED Display & Lighting
Category
Out-Of-Home Media

Our Process

How We Work

  1. 1

    Define The Application

    We establish viewing distance and pitch, brightness requirement, ambient light, mounting and service access, environment, control system and any photometric or code requirement that applies.

  2. 2

    Design & Prototype

    Optical, thermal, electrical and mechanical design is developed with thermal modeling and a prototype or sample module for approval, including measured temperatures and photometric data.

  3. 3

    Manufacture & Calibrate

    Modules are assembled, drivers integrated, enclosures fabricated and sealed, and modules calibrated for brightness and color with calibration data retained against each unit.

  4. 4

    Burn In, Test & Support

    Product is burned in and tested electrically, photometrically and for ingress protection, then shipped with documentation and commissioning support for installation and control configuration.

Track Record

By The Numbers

50,000 m2Display Area Produced
72 hrStandard Burn-In Duration
IP65Outdoor Cabinet Rating
15 yrsLED Product Engineering Experience

Specifying A Display Or Lighting Package?

Send the application details to TDE-lighttech and we will return a design with measured thermal data and photometric information.

FAQ

Technical quotations with pitch options are issued within three days.

Questions & Answers

Frequently Asked Questions

It is a lumen maintenance projection derived from standardized testing and extrapolation, and it is only meaningful alongside the drive current and junction temperature it was derived at. The same diode can be rated very differently depending on how hard it is driven and how well it is cooled.

Because drivers contain electrolytic components that age rapidly with temperature, and many products place them in the hottest part of the fixture with little derating. We derate for the installed ambient and design for field driver replacement rather than treating the fixture as disposable.

Almost always binning or thermal. Diodes from loose brightness and color bins drift apart at different rates, and modules running hot lose output faster. Calibration at commissioning masks the problem initially, which is why it appears gradually rather than immediately.

With our displays, yes, because calibration data is stored per module and diodes are tightly binned. Products built without binning discipline or calibration storage generally need the surrounding area recalibrated, and sometimes the whole wall.

Yes, with engineering input during design. Curved and irregular geometry creates thermal and service access problems that are inexpensive to solve on paper and very expensive to solve on a finished installation, so we raise them early.

It is necessary but not sufficient. Thermal cycling, ultraviolet degradation, condensation inside the cabinet, surge exposure and wind loading all matter, and a cabinet that passes a water test can still fail from internal condensation. We design and test for the whole set of conditions.

Our Advantages

Why Clients Choose Us

Burn-In Before Shipment

Extended run-in catches infant mortality in our plant, which is the difference between a warranty statistic and a roof access call.

Outdoor Ratings Actually Tested

Ingress protection is validated rather than assumed from a gasket specification, and surge protection is sized for genuine installation exposure.

Thermal Design Verified By Measurement

Junction and case temperatures are measured rather than estimated, because junction temperature is what actually governs lumen maintenance.

Serviceable, Not Disposable

Products are built so a driver or module can be replaced in the field, instead of requiring the whole fixture or cabinet to be discarded.

Drivers Derated Properly

Drivers are selected with margin for the installed ambient, addressing the single most common cause of premature LED product failure.

Diodes Binned, Modules Calibrated

Brightness and color binning plus module-level calibration keep a wall reading as a single surface, including after a panel is replaced years later.

Drivers Derated Properly

Power supplies run with real margin against their rating, since the driver, not the diode, is what usually fails first in a display or luminaire.

Outdoor Ratings Actually Tested

Enclosures are tested for ingress and thermal cycling as built, not credited with the rating of an individual component inside them.

Diodes Binned, Modules Calibrated

Brightness and wavelength binning plus per-module calibration is what stops a large wall looking like a patchwork two years into its life.

Get In Touch

Technical quotations with pitch options are issued within three days.

Contact Us

Contact

Contact

Get In Touch

Technical quotations with pitch options are issued within three days.

  • Office AddressTankval 5, 2408 ZC Alphen aan den Rijn
  • Telephone+31206973849
  • Business HoursMonday to Friday, 8:30 - 17:30
  • Emergency & After-Hours24/7 dispatch for contracted clients
  • Websitetde-lighttechled.com

Technical quotations with pitch options are issued within three days.

Sectors

Who We Serve

Indoor fine pitch and outdoor billboard products share the same test discipline.

  • Sign & Display Integrators
  • Stadium & Venue Operators
  • Retail Chain Developers
  • Transit & Transportation Authorities
  • Industrial Facility Owners
  • Broadcast & Studio Builders
  • Architectural Lighting Designers
  • Commercial Electrical Contractors

Image Credits

Photographs on this website are used under open licenses that permit commercial use.

The following images are published under Creative Commons licenses and are listed with their original title and attribution as given by the source.

  • serviceSource: fal-flux-2 | License: AI GENERATED
  • serviceSource: fal-flux-2 | License: AI GENERATED
  • serviceSource: fal-flux-2 | License: AI GENERATED
  • serviceSource: fal-flux-2 | License: AI GENERATED
  • aboutSource: fal-flux-2 | License: AI GENERATED
  • aboutSource: fal-flux-2 | License: AI GENERATED
  • serviceSource: fal-flux-2 | License: AI GENERATED
  • serviceSource: fal-flux-2 | License: AI GENERATED
  • projectSource: fal-flux-2 | License: AI GENERATED
  • heroSource: fal-flux-2 | License: AI GENERATED
  • clientSource: fal-flux-2 | License: AI GENERATED
  • projectSource: fal-flux-2 | License: AI GENERATED
  • clientSource: fal-flux-2 | License: AI GENERATED
  • projectSource: fal-flux-2 | License: AI GENERATED
  • heroSource: fal-flux-2 | License: AI GENERATED
  • projectSource: fal-flux-2 | License: AI GENERATED

Driver Integration

Built For Outdoor Weather, Not Showrooms

Outdoor displays face water ingress, ultraviolet degradation, thermal cycling and wind loading. We build and test for those conditions, with sealed cabinets, service access and surge protection sized for real installations.

  • Modules Calibrated
  • Serviceable
  • Spares Kept
  • Thermal Measured
LED Display & Lighting services by TDE-lighttech B.V.
LED Display & Lighting

Every panel burned in before it leaves the factory

  • ISO 9001 Quality Management
  • IES LM-80 LED Lumen Maintenance Testing
  • IES TM-21 Lifetime Projection Methods
  • UL 8750 LED Equipment Safety
  • IEC 60529 Ingress Protection Ratings

Our Services

What We Do

01

Outdoor Display & Billboard Systems

Weather-rated display cabinets with tested ingress protection, ultraviolet stable masking and louvers, surge protection, thermal management for solar gain and serviceable module access. Outdoor failures cluster

View Details
02

Burn-In, Testing & Quality Documentation

Extended burn-in of finished product, electrical safety and photometric verification, ingress protection validation, color uniformity measurement and documented quality records. Early-life failures are found in

View Details
03

LED Driver & Power Supply Integration

Selection and integration of drivers and power supplies with attention to derating, ripple, dimming protocol compatibility, inrush, surge immunity and operating temperature. Drivers are the most common failure

View Details
04

Industrial & Commercial Luminaires

Manufacture of high bay, low bay, area, flood, linear and task luminaires with documented photometric performance, driver derating for the installed ambient temperature and heat sink design verified by thermal

View Details
05

Fine Pitch Indoor Display Manufacturing

Production of indoor video wall modules and cabinets in close pixel pitches with binned diodes, module-level calibration for brightness and color uniformity, and cabinet construction designed for front or rear

View Details
06

Custom Signage & Architectural Fabrication

Bespoke LED signage, channel lettering, curved and irregular display surfaces, and architectural lighting elements fabricated to designer intent with structural and electrical engineering support. Custom geomet

View Details

Track Record

By The Numbers

50,000 m2Display Area Produced
72 hrStandard Burn-In Duration
IP65Outdoor Cabinet Rating
15 yrsLED Product Engineering Experience

Our Advantages

Why Clients Choose Us

Burn-In Before Shipment

Extended run-in catches infant mortality in our plant, which is the difference between a warranty statistic and a roof access call.

Outdoor Ratings Actually Tested

Ingress protection is validated rather than assumed from a gasket specification, and surge protection is sized for genuine installation exposure.

Thermal Design Verified By Measurement

Junction and case temperatures are measured rather than estimated, because junction temperature is what actually governs lumen maintenance.

Serviceable, Not Disposable

Products are built so a driver or module can be replaced in the field, instead of requiring the whole fixture or cabinet to be discarded.

Drivers Derated Properly

Drivers are selected with margin for the installed ambient, addressing the single most common cause of premature LED product failure.

Diodes Binned, Modules Calibrated

Brightness and color binning plus module-level calibration keep a wall reading as a single surface, including after a panel is replaced years later.

Drivers Derated Properly

Power supplies run with real margin against their rating, since the driver, not the diode, is what usually fails first in a display or luminaire.

Outdoor Ratings Actually Tested

Enclosures are tested for ingress and thermal cycling as built, not credited with the rating of an individual component inside them.

Diodes Binned, Modules Calibrated

Brightness and wavelength binning plus per-module calibration is what stops a large wall looking like a patchwork two years into its life.

Our Process

How We Work

  1. 1

    Define The Application

    We establish viewing distance and pitch, brightness requirement, ambient light, mounting and service access, environment, control system and any photometric or code requirement that applies.

  2. 2

    Design & Prototype

    Optical, thermal, electrical and mechanical design is developed with thermal modeling and a prototype or sample module for approval, including measured temperatures and photometric data.

  3. 3

    Manufacture & Calibrate

    Modules are assembled, drivers integrated, enclosures fabricated and sealed, and modules calibrated for brightness and color with calibration data retained against each unit.

  4. 4

    Burn In, Test & Support

    Product is burned in and tested electrically, photometrically and for ingress protection, then shipped with documentation and commissioning support for installation and control configuration.

Projects & Case Studies

Selected Work

High Bay Luminaires For Distribution CenterIndustrial Lighting

High Bay Luminaires For Distribution Center

Fixtures were produced with drivers derated for the measured ambient at roof level, heat sinks verified by thermal testing, and field-replaceable drivers. Photometric data supported the lighting design calculation submitted for approval.

View Details
Fine Pitch Wall For Broadcast StudioBroadcast

Fine Pitch Wall For Broadcast Studio

A close pitch video wall was produced with tightly binned diodes and module calibration data stored per panel, plus front service access for a studio with no rear clearance. Replacement panels installed since have blended without recalibrating the wall.

View Details
Curved Architectural Display ElementArchitectural

Curved Architectural Display Element

A curved display surface for a building lobby required custom module geometry. Thermal and service access problems were resolved during design, and structural and electrical engineering support was provided to the installing contractor.

View Details
Outdoor Billboard System For Transit HubOut-Of-Home Media

Outdoor Billboard System For Transit Hub

A weather-rated display was built with validated ingress protection, surge protection sized for the exposed location, internal airflow managed for solar gain and serviceable modules accessible from a single side given the structural constraints.

View Details

From Our Desk

Insights & Updates

LED Display & Lighting - Project

Why Binning Shows Up Two Years Later

Loosely binned diodes drift apart at different rates. Calibration hides it at first, which is why display uniformity problems appear gradually.

LED Display & Lighting - Hero

Drivers Are The Weak Link

Electrolytic components age with temperature. Derating for installed ambient and designing for field replacement rather than disposal.

LED Display & Lighting - Client

Junction Temperature Decides LED Lifetime

Lumen maintenance is a thermal story. How heat path design and drive current interact, and why a lifetime figure without conditions means nothing.

LED Display & Lighting - Project

Outdoor Cabinets Beyond The IP Rating

Condensation, thermal cycling, ultraviolet exposure and surge all matter. What a water ingress test does not tell you about a rooftop installation.

Client Feedback

What Clients Say

Replacement panels blend into the wall without recalibration, two years after installation. That is the detail that separates a real manufacturer from an assembler.
A
A. PetrosyanTechnical Director, Display Integrator
They derated the drivers for the actual temperature at our roof level, which nobody else asked about. Three years in, we have not replaced one.
J
J. ThibodeauxFacilities Manager, Distribution Client
Our curved lobby element had thermal and access problems that they flagged during design. Solving them on paper saved a very awkward site discovery.
M
M. HaugenPrincipal, Lighting Design Practice

Specifying A Display Or Lighting Package?

Send the application details to TDE-lighttech and we will return a design with measured thermal data and photometric information.